While PTTing the HT via a hotspot (Connection to HBlink server)


Alejandro Pereida
 

While PTTing my HT via a hotspot in the same network where we have our HBlink server, I can see (by  doing a #tail -f /tmp/hblink.log) that

there is an error:

 

INFO 2020-10-06 17:21:17,274 (MASTER-1) *CALL START* STREAM ID: 3146637437 SUB: 1106297 (1106297) PEER: 1106297 (1106297) TGID 33426 (33426), TS 2

INFO 2020-10-06 17:21:17,276 (MASTER-1) Conference Bridge: SONORA, Call Bridged to HBP System: REPEATER-1 TS: 2, TGID: 33426

ERROR 2020-10-06 17:21:17,995 (MASTER-1) Unrecognized command. Raw HBP PDU: b'444d52410010e17910e17900484e3249580000'

 

Does anyone know why we are getting this and how to solve it?

 

Thanks in advance

 

Alex N2IX


Cort N0MJS <n0mjs@...>
 

That’s a DMRA packet, which would appear to be a HBP packet for DMR Talker Alias. HBlink does not process those currently. The “error" will not affect functionality.

On Oct 6, 2020, at 7:31 PM, Alejandro Pereida via groups.io <xe2_bss@...> wrote:

While PTTing my HT via a hotspot in the same network where we have our HBlink server, I can see (by  doing a #tail -f /tmp/hblink.log) that
there is an error:
 
INFO 2020-10-06 17:21:17,274 (MASTER-1) *CALL START* STREAM ID: 3146637437 SUB: 1106297 (1106297) PEER: 1106297 (1106297) TGID 33426 (33426), TS 2
INFO 2020-10-06 17:21:17,276 (MASTER-1) Conference Bridge: SONORA, Call Bridged to HBP System: REPEATER-1 TS: 2, TGID: 33426
ERROR 2020-10-06 17:21:17,995 (MASTER-1) Unrecognized command. Raw HBP PDU: b'444d52410010e17910e17900484e3249580000'
 
Does anyone know why we are getting this and how to solve it?
 
Thanks in advance
 
Alex N2IX

Cort Buffington
785-865-7206


Alejandro Pereida
 

Thanks Cort

 

From: <HBlink@DVSwitch.groups.io> on behalf of "Cort N0MJS via groups.io" <n0mjs@...>
Reply-To: <HBlink@DVSwitch.groups.io>
Date: Wednesday, October 7, 2020 at 11:28 AM
To: "HBlink@dvswitch.groups.io" <HBlink@DVSwitch.groups.io>
Subject: Re: [HBlink] While PTTing the HT via a hotspot (Connection to HBlink server)

 

That’s a DMRA packet, which would appear to be a HBP packet for DMR Talker Alias. HBlink does not process those currently. The “error" will not affect functionality.



On Oct 6, 2020, at 7:31 PM, Alejandro Pereida via groups.io <xe2_bss@...> wrote:

 

While PTTing my HT via a hotspot in the same network where we have our HBlink server, I can see (by  doing a #tail -f /tmp/hblink.log) that

there is an error:

 

INFO 2020-10-06 17:21:17,274 (MASTER-1) *CALL START* STREAM ID: 3146637437 SUB: 1106297 (1106297) PEER: 1106297 (1106297) TGID 33426 (33426), TS 2

INFO 2020-10-06 17:21:17,276 (MASTER-1) Conference Bridge: SONORA, Call Bridged to HBP System: REPEATER-1 TS: 2, TGID: 33426

ERROR 2020-10-06 17:21:17,995 (MASTER-1) Unrecognized command. Raw HBP PDU: b'444d52410010e17910e17900484e3249580000'

 

Does anyone know why we are getting this and how to solve it?

 

Thanks in advance

 

Alex N2IX

 

Cort Buffington

785-865-7206

 


Alejandro Pereida
 

Cort I found something interesting that may give you a clue of why the error is happening even though it does not affect functionality of the HBLink:

 

If I use my Anytone D878 I get the the error I posted below, If I use my Motorola XPR7550e I don’t get any error at all, I did this experiment

several times and it is the same result, the Anytone D878 will cause that error to appear in the hblink.log file and the Motorola handheld does not produce any

errors at all while transmitting to my hotspot connected to the HBLink server.

 

 

 

From: <HBlink@DVSwitch.groups.io> on behalf of "Cort N0MJS via groups.io" <n0mjs@...>
Reply-To: <HBlink@DVSwitch.groups.io>
Date: Wednesday, October 7, 2020 at 11:28 AM
To: "HBlink@dvswitch.groups.io" <HBlink@DVSwitch.groups.io>
Subject: Re: [HBlink] While PTTing the HT via a hotspot (Connection to HBlink server)

 

That’s a DMRA packet, which would appear to be a HBP packet for DMR Talker Alias. HBlink does not process those currently. The “error" will not affect functionality.



On Oct 6, 2020, at 7:31 PM, Alejandro Pereida via groups.io <xe2_bss@...> wrote:

 

While PTTing my HT via a hotspot in the same network where we have our HBlink server, I can see (by  doing a #tail -f /tmp/hblink.log) that

there is an error:

 

INFO 2020-10-06 17:21:17,274 (MASTER-1) *CALL START* STREAM ID: 3146637437 SUB: 1106297 (1106297) PEER: 1106297 (1106297) TGID 33426 (33426), TS 2

INFO 2020-10-06 17:21:17,276 (MASTER-1) Conference Bridge: SONORA, Call Bridged to HBP System: REPEATER-1 TS: 2, TGID: 33426

ERROR 2020-10-06 17:21:17,995 (MASTER-1) Unrecognized command. Raw HBP PDU: b'444d52410010e17910e17900484e3249580000'

 

Does anyone know why we are getting this and how to solve it?

 

Thanks in advance

 

Alex N2IX

 

Cort Buffington

785-865-7206

 


Cort N0MJS <n0mjs@...>
 

Anytone D878 does talker alias. No Motorola radios do. The opcode type is “DMRA” for talker alias and that’s the 4-byte opcode of the error message. This isn’t a new situation. It has  come up before.

On Oct 7, 2020, at 3:35 PM, Alejandro Pereida via groups.io <xe2_bss@...> wrote:

Cort I found something interesting that may give you a clue of why the error is happening even though it does not affect functionality of the HBLink:
 
If I use my Anytone D878 I get the the error I posted below, If I use my Motorola XPR7550e I don’t get any error at all, I did this experiment
several times and it is the same result, the Anytone D878 will cause that error to appear in the hblink.log file and the Motorola handheld does not produce any
errors at all while transmitting to my hotspot connected to the HBLink server.
 
 
 
From: <HBlink@DVSwitch.groups.io> on behalf of "Cort N0MJS via groups.io" <n0mjs@...>
Reply-To: <HBlink@DVSwitch.groups.io>
Date: Wednesday, October 7, 2020 at 11:28 AM
To: "HBlink@dvswitch.groups.io" <HBlink@DVSwitch.groups.io>
Subject: Re: [HBlink] While PTTing the HT via a hotspot (Connection to HBlink server)
 
That’s a DMRA packet, which would appear to be a HBP packet for DMR Talker Alias. HBlink does not process those currently. The “error" will not affect functionality.


On Oct 6, 2020, at 7:31 PM, Alejandro Pereida via groups.io <xe2_bss@...> wrote:
 
While PTTing my HT via a hotspot in the same network where we have our HBlink server, I can see (by  doing a #tail -f /tmp/hblink.log) that
there is an error:
 
INFO 2020-10-06 17:21:17,274 (MASTER-1) *CALL START* STREAM ID: 3146637437 SUB: 1106297 (1106297) PEER: 1106297 (1106297) TGID 33426 (33426), TS 2
INFO 2020-10-06 17:21:17,276 (MASTER-1) Conference Bridge: SONORA, Call Bridged to HBP System: REPEATER-1 TS: 2, TGID: 33426
ERROR 2020-10-06 17:21:17,995 (MASTER-1) Unrecognized command. Raw HBP PDU: b'444d52410010e17910e17900484e3249580000'
 
Does anyone know why we are getting this and how to solve it?
 
Thanks in advance
 
Alex N2IX
 
Cort Buffington
785-865-7206
 


Cort Buffington
785-865-7206


Alejandro Pereida
 

Thanks again Cort for the info

 

From: <HBlink@DVSwitch.groups.io> on behalf of "Cort N0MJS via groups.io" <n0mjs@...>
Reply-To: <HBlink@DVSwitch.groups.io>
Date: Wednesday, October 7, 2020 at 1:41 PM
To: "HBlink@dvswitch.groups.io" <HBlink@DVSwitch.groups.io>
Subject: Re: [HBlink] While PTTing the HT via a hotspot (Connection to HBlink server)

 

Anytone D878 does talker alias. No Motorola radios do. The opcode type is “DMRA” for talker alias and that’s the 4-byte opcode of the error message. This isn’t a new situation. It has  come up before.



On Oct 7, 2020, at 3:35 PM, Alejandro Pereida via groups.io <xe2_bss@...> wrote:

 

Cort I found something interesting that may give you a clue of why the error is happening even though it does not affect functionality of the HBLink:

 

If I use my Anytone D878 I get the the error I posted below, If I use my Motorola XPR7550e I don’t get any error at all, I did this experiment

several times and it is the same result, the Anytone D878 will cause that error to appear in the hblink.log file and the Motorola handheld does not produce any

errors at all while transmitting to my hotspot connected to the HBLink server.

 

 

 

From: <HBlink@DVSwitch.groups.io> on behalf of "Cort N0MJS via groups.io" <n0mjs@...>
Reply-To: <HBlink@DVSwitch.groups.io>
Date: Wednesday, October 7, 2020 at 11:28 AM
To: "HBlink@dvswitch.groups.io" <HBlink@DVSwitch.groups.io>
Subject: Re: [HBlink] While PTTing the HT via a hotspot (Connection to HBlink server)

 

That’s a DMRA packet, which would appear to be a HBP packet for DMR Talker Alias. HBlink does not process those currently. The “error" will not affect functionality.




On Oct 6, 2020, at 7:31 PM, Alejandro Pereida via groups.io <xe2_bss@...> wrote:

 

While PTTing my HT via a hotspot in the same network where we have our HBlink server, I can see (by  doing a #tail -f /tmp/hblink.log) that

there is an error:

 

INFO 2020-10-06 17:21:17,274 (MASTER-1) *CALL START* STREAM ID: 3146637437 SUB: 1106297 (1106297) PEER: 1106297 (1106297) TGID 33426 (33426), TS 2

INFO 2020-10-06 17:21:17,276 (MASTER-1) Conference Bridge: SONORA, Call Bridged to HBP System: REPEATER-1 TS: 2, TGID: 33426

ERROR 2020-10-06 17:21:17,995 (MASTER-1) Unrecognized command. Raw HBP PDU: b'444d52410010e17910e17900484e3249580000'

 

Does anyone know why we are getting this and how to solve it?

 

Thanks in advance

 

Alex N2IX

 

Cort Buffington

785-865-7206

 

 

Cort Buffington

785-865-7206

 


Corey Dean N3FE
 

You Can disable the TA on send in the 878 and that should fix the problem.


On Oct 7, 2020, at 4:35 PM, Alejandro Pereida via groups.io <xe2_bss@...> wrote:



Cort I found something interesting that may give you a clue of why the error is happening even though it does not affect functionality of the HBLink:

 

If I use my Anytone D878 I get the the error I posted below, If I use my Motorola XPR7550e I don’t get any error at all, I did this experiment

several times and it is the same result, the Anytone D878 will cause that error to appear in the hblink.log file and the Motorola handheld does not produce any

errors at all while transmitting to my hotspot connected to the HBLink server.

 

 

 

From: <HBlink@DVSwitch.groups.io> on behalf of "Cort N0MJS via groups.io" <n0mjs@...>
Reply-To: <HBlink@DVSwitch.groups.io>
Date: Wednesday, October 7, 2020 at 11:28 AM
To: "HBlink@dvswitch.groups.io" <HBlink@DVSwitch.groups.io>
Subject: Re: [HBlink] While PTTing the HT via a hotspot (Connection to HBlink server)

 

That’s a DMRA packet, which would appear to be a HBP packet for DMR Talker Alias. HBlink does not process those currently. The “error" will not affect functionality.



On Oct 6, 2020, at 7:31 PM, Alejandro Pereida via groups.io <xe2_bss@...> wrote:

 

While PTTing my HT via a hotspot in the same network where we have our HBlink server, I can see (by  doing a #tail -f /tmp/hblink.log) that

there is an error:

 

INFO 2020-10-06 17:21:17,274 (MASTER-1) *CALL START* STREAM ID: 3146637437 SUB: 1106297 (1106297) PEER: 1106297 (1106297) TGID 33426 (33426), TS 2

INFO 2020-10-06 17:21:17,276 (MASTER-1) Conference Bridge: SONORA, Call Bridged to HBP System: REPEATER-1 TS: 2, TGID: 33426

ERROR 2020-10-06 17:21:17,995 (MASTER-1) Unrecognized command. Raw HBP PDU: b'444d52410010e17910e17900484e3249580000'

 

Does anyone know why we are getting this and how to solve it?

 

Thanks in advance

 

Alex N2IX

 

Cort Buffington

785-865-7206