Re: BrandMeister to XLX


Steve N4IRS
 

Yes, it's possible to do this. It would take 2 instances of MMDVM_Bridge. One connected to BM and the second connected to XLX. Each MMDVM_Bridge would need to be in a separate directory so that each MMDVM_Bridge would have a local copy of DVSwitch.ini and MMDVM_Bridge.ini

As always, buld from the outside in. Connect the first MMDVM_Bridge to BM. Make sure it's logging in properly and receiving data from BM. The connect the second MMDVM_Bridge to XLX. Make sure it's logging in and receiving data.

Point the DMR TX and RX port at the XLX RX and TX ports. Traffic should pass from XLX to BM. Run each program in the foreground so you can watch waht is happening.

73, Steve N4IRS
  

On 05/10/2018 10:12 AM, ea5gvk@... wrote:
How can I bridge a TG xxx DMR from Brandmeister to a Reflector XLX xxx Room X DMR?
please.
Would there be any way to incorporate this possibility in the MMDVM_Bridge?
Thank you.

Join main@DVSwitch.groups.io to automatically receive all group messages.