Re: Brandmeister


Steve N4IRS
 

Below is a section of my conference bridge configuration for confbridge.py
The DMR-MARC is a connection to a c-Bridge and BM_3108 is a connection to BrandMeister.
Walton, IRSC etc are my repeaters.

Hope this helps.


    'STATEWIDE': [
            {'SYSTEM': 'DMR-MARC',  'TS': 2, 'TGID': 3112,    'ACTIVE': True, 'TIMEOUT': 2,  'TO_TYPE': 'NONE', 'ON': [],         'OFF': []},
            {'SYSTEM': 'STN2100',   'TS': 2, 'TGID': 3112,    'ACTIVE': True, 'TIMEOUT': 2,  'TO_TYPE': 'NONE', 'ON': [],         'OFF': []},
            {'SYSTEM': 'Walton',    'TS': 2, 'TGID': 3112,    'ACTIVE': True, 'TIMEOUT': 2,  'TO_TYPE': 'NONE', 'ON': [],         'OFF': []},
            {'SYSTEM': 'IRSC',      'TS': 2, 'TGID': 3112,    'ACTIVE': True, 'TIMEOUT': 2,  'TO_TYPE': 'NONE', 'ON': [],         'OFF': []},
            {'SYSTEM': 'N4IRR',     'TS': 2, 'TGID': 3112,    'ACTIVE': True, 'TIMEOUT': 2,  'TO_TYPE': 'NONE', 'ON': [],         'OFF': []},
            {'SYSTEM': 'N4IRS',     'TS': 2, 'TGID': 3112,    'ACTIVE': True, 'TIMEOUT': 2,  'TO_TYPE': 'NONE', 'ON': [],         'OFF': []},
       ],

    'TAC310': [
            {'SYSTEM': 'DMR-MARC',  'TS': 2, 'TGID': 310,     'ACTIVE': True,  'TIMEOUT': 2, 'TO_TYPE': 'NONE', 'ON': [],         'OFF': []},
            {'SYSTEM': 'STN2100',   'TS': 2, 'TGID': 310,     'ACTIVE': True,  'TIMEOUT': 2, 'TO_TYPE': 'ON',   'ON': [310,],     'OFF': []},
            {'SYSTEM': 'Walton',    'TS': 2, 'TGID': 310,     'ACTIVE': True,  'TIMEOUT': 2, 'TO_TYPE': 'ON',   'ON': [310,],     'OFF': []},
            {'SYSTEM': 'IRSC',      'TS': 2, 'TGID': 310,     'ACTIVE': True,  'TIMEOUT': 2, 'TO_TYPE': 'ON',   'ON': [310,],     'OFF': []},
            {'SYSTEM': 'N4IRR',     'TS': 2, 'TGID': 310,     'ACTIVE': True,  'TIMEOUT': 2, 'TO_TYPE': 'ON',   'ON': [310,],     'OFF': []},
            {'SYSTEM': 'N4IRS',     'TS': 2, 'TGID': 310,     'ACTIVE': True,  'TIMEOUT': 2, 'TO_TYPE': 'ON',   'ON': [310,],     'OFF': []},
        ],

    'TCOAST': [
            {'SYSTEM': 'BM_3108',   'TS': 2, 'TGID': 31123,   'ACTIVE': True, 'TIMEOUT': 2,  'TO_TYPE': 'NONE', 'ON': [],         'OFF': []},
            {'SYSTEM': 'STN2100',   'TS': 2, 'TGID': 31123,   'ACTIVE': True, 'TIMEOUT': 2,  'TO_TYPE': 'NONE', 'ON': [],         'OFF': []},
            {'SYSTEM': 'Walton',    'TS': 2, 'TGID': 31123,   'ACTIVE': True, 'TIMEOUT': 2,  'TO_TYPE': 'NONE', 'ON': [],         'OFF': []},
            {'SYSTEM': 'IRSC',      'TS': 2, 'TGID': 31123,   'ACTIVE': True, 'TIMEOUT': 2,  'TO_TYPE': 'NONE', 'ON': [],         'OFF': []},
            {'SYSTEM': 'N4IRR',     'TS': 2, 'TGID': 31123,   'ACTIVE': True, 'TIMEOUT': 2,  'TO_TYPE': 'NONE', 'ON': [],         'OFF': []},
            {'SYSTEM': 'N4IRS',     'TS': 2, 'TGID': 31123,   'ACTIVE': True, 'TIMEOUT': 2,  'TO_TYPE': 'NONE', 'ON': [],         'OFF': []},
        ],


On 6/29/2017 10:46 AM, David Andrzejewski KD8TWG via Groups.Io wrote:
It's a Motorola repeater.  I'm currently using DMRLink's confbridge to connect to it and to the K4USD cBridge, both via IPSC. My thought here is that we could potentially carry select additional talk groups and/or reflectors from BrandMeister as well as the standard talk groups we get from K4USD.  Obviously I wouldn't bridge anything between K4USD and BM, only between those two sources and the repeater. :)
_._,_._,_

Join main@DVSwitch.groups.io to automatically receive all group messages.