Re: Multiple MMDVM _Bridge instances with brandmeister?


Skyler Fennell
 

310847 is the talk-group I want to connect to not a DMR ID. If I try 31084701, it does not talk on the proper talk-group since that is not even a valid talk group. 

So again, here is my audio desired flowcharts:

YSF REFLECTOR < -- > MMDVM_BRIDGE <---> BRANDMEISTER TALKGROUP <--> MMDVM_BRIDGE <--> ANALOG_BRIDGE <--> ASL

BRANDMEISTER TALKGROUP --->  MMDVM_BRIDGE --> ANALOG_BRIDGE --> ASL
&&BRANDMEISTER TALKGROUP --->  MMDBM_BRIDGE --> YSF REFLECTOR


I already have tried appending different DMR digits, and even am using someone elses call for the second bridge with the DMR ID. I also changed all of the DVSWITCH ports so there is no conflict on the local ports.

1St MMDVM_BRIDGE.ini 


[General]

Callsign=KG0SKY

Id=MY_ID with 01 at the end

Timeout=180

Duplex=0

RFModeHang=10

NetModeHang=3


[DMR Network]

Enable=1

Address=107.191.99.14

Port=62031

Jitter=360

Local=62032

Password=passw0rd

Slot1=1

Slot2=1

Debug=0


2nd MMDVM_Bridge.ini

[General]

Callsign=KE0VH

Id=KE0VH's ID NUMBER HERE

Timeout=180

Duplex=0

RFModeHang=10

NetModeHang=3


[DMR Network]

Enable=1

Address=3102.repeater.net

Port=62031

Jitter=360

Local=62032

Password=passw0rd

Slot1=1

Slot2=1

Debug=0



1st DVSwitch.ini

[DMR]

Address = 127.0.0.1             ; Address to send AMBE TLV frames to (export)

TXPort = 31100                  ; Port to send AMBE TLV frames to (export)

RXPort = 31103                  ; Port to listen on (import)

Slot = 2                        ; Export slot


2nd DVSwitch.ini

[DMR]

Address = 127.0.0.1             ; Address to send AMBE TLV frames to (export)

TXPort = 31106                  ; Port to send AMBE TLV frames to (export)

RXPort = 31109                  ; Port to listen on (import)

Slot = 1                        ; Export slot

[YSF]


Address = 127.0.0.1             ; Address to send AMBE TLV frames to (export)

TXPort = 31109                  ; Port to send AMBE TLV frames to (export)

RXPort = 31106                  ; Port to listen on (import)

FallbackID = MY_ID_IS_HERE            ; In case we can not find a valid DMR id in the database, export this one

ExportTG = 310847                 ; Which TG to export

Slot = 1                        ; Export slot



Analog_Bridge

[AMBE_AUDIO]

address = 127.0.0.1                     ; IP address of xx_Bridge

txPort = 31103                          ; Transmit TLV frames to partner on this port

rxPort = 31100                          ; Listen for TLV frames from partner on this port

ambeMode = DMR

minTxTimeMS = 100                      ; Minimum time in MS for hang delay (0-10000)


; The metadata below is used when ASL is the source since it does not have any concept of digital$

gatewayDmrId = MY_ID                        ; ID to use when transmitting from Analog_Bridge

repeaterID = MY_ID_WITH_01_AFTER_IT                          ; ID of source repeater

txTg = 310847                              ; TG to use for all frames sent from Analog_Bridge -> $

txTs = 1                                ; Slot to use for frames sent from Analog_Bridge -> xx_Br$

colorCode = 1                           ; Color Code to assign DMR frames 



Could this be a port conflict on the DMR master registration and are there alternate ports I can use?


On Sat, Feb 23, 2019 at 2:35 PM Mike KB8JNM <groupio@...> wrote:
I think you need to append your dmr id's with extra 1 or 2 digits and
make them different.

310847 =
31084701
31084702

On 2/23/2019 4:31 PM, Skyler Fennell wrote:
> I am attempting to run TWO instances of MMDVM bridge. I made separate
> folders for each, and now am trying to run them both from command line.
>
> ONE is for DMR  310847 -->> ANALOG AllStar
>
> The OTHER is for YSF --> DMR 310847.
>
> Both YSF and Analog need to talk to the same DMR Brandmeister talkgroup. I
> am using separate ID callsigns for the YSF bridge and the Analog_Bridge
>
> They both work perfectly standalone, but, when I try to run both, I get
> registration errors on Brandmeister:
>
> W: 2019-02-23 21:28:40.566 DMR, Login to the master has failed, retrying
> login ...
>
>
>
>
> Is it possible to have TWO nodes connected to a brandmeister talkgroup from
> the same server?
>
>
> Skyler
>
>
>
>



Join main@DVSwitch.groups.io to automatically receive all group messages.