Re: #brandmeister #brandmeister


Steve N4IRS
 

Set duplex = 0
frequencies to simplex
make sure callsign and dmrID point to correct user.

What does the log show?

On 3/23/2021 12:10 PM, Bill Kittilson wrote:

I am no longer able to connect to brandmister,  I checked with brandmister and I am not blocked.   I did enable my password and changed the MMDVM_bridge.ini file.  I did fix the frequency in the file also.  

 

Is this the current version of MMDVM_Bridge  1.01-20180420-3?

 

 

[DMR Network]

Enable=1

Address=3103.repeater.net

Jitter=360

Local=62031

Password=mypassword

# for DMR+ see https://github.com/DVSwitch/MMDVM_Bridge/blob/master/DOC/DMRplus_startup_options.md

# for XLX the syntax is: Options=XLX:4009

# Options=

Slot1=0

Slot2=1

Debug=1

 

 

Any ideas?

 

 

Thanks

Bill N3JHS


Join main@DVSwitch.groups.io to automatically receive all group messages.