Date   

moderated Re: Compile Error in M172DMR - md380_vocoder.h missing

Steve N4IRS
 

Jeff,
I suggest you ask in the github area.

Sent by smoke signal (AT&T)


From: main@DVSwitch.groups.io <main@DVSwitch.groups.io> on behalf of Jeff - WA3PNY via groups.io <bauerjv@...>
Sent: Sunday, April 11, 2021 12:58:27 PM
To: main@DVSwitch.groups.io <main@DVSwitch.groups.io>
Subject: [DVSwitch] Compile Error in M172DMR - md380_vocoder.h missing
 
I must be missing something obvious, I git cloned the Nostar branch of MMDVM_CM, and am attempting to compile M172DMR module, and it errors out not finding md380_vocoder.h  I'm compiling on a HP server, and a bunch of md380_vocoders seem to be nailed into ARM.  Here is what I am seeing:

bauerjv@penn-link4:~/Downloads/M17/MMDVM_CM/M172DMR$ sudo make
g++ -g -O3 -Wall -std=c++0x -pthread -c -o BPTC19696.o BPTC19696.cpp
g++ -g -O3 -Wall -std=c++0x -pthread -c -o Conf.o Conf.cpp
g++ -g -O3 -Wall -std=c++0x -pthread -c -o CRC.o CRC.cpp
g++ -g -O3 -Wall -std=c++0x -pthread -c -o DelayBuffer.o DelayBuffer.cpp
g++ -g -O3 -Wall -std=c++0x -pthread -c -o DMRData.o DMRData.cpp
g++ -g -O3 -Wall -std=c++0x -pthread -c -o DMREMB.o DMREMB.cpp
g++ -g -O3 -Wall -std=c++0x -pthread -c -o DMREmbeddedData.o DMREmbeddedData.cpp
g++ -g -O3 -Wall -std=c++0x -pthread -c -o DMRFullLC.o DMRFullLC.cpp
g++ -g -O3 -Wall -std=c++0x -pthread -c -o DMRLC.o DMRLC.cpp
g++ -g -O3 -Wall -std=c++0x -pthread -c -o DMRLookup.o DMRLookup.cpp
g++ -g -O3 -Wall -std=c++0x -pthread -c -o DMRNetwork.o DMRNetwork.cpp
g++ -g -O3 -Wall -std=c++0x -pthread -c -o DMRSlotType.o DMRSlotType.cpp
g++ -g -O3 -Wall -std=c++0x -pthread -c -o M17Network.o M17Network.cpp
g++ -g -O3 -Wall -std=c++0x -pthread -c -o Golay2087.o Golay2087.cpp
g++ -g -O3 -Wall -std=c++0x -pthread -c -o Golay24128.o Golay24128.cpp
g++ -g -O3 -Wall -std=c++0x -pthread -c -o Hamming.o Hamming.cpp
g++ -g -O3 -Wall -std=c++0x -pthread -c -o Log.o Log.cpp
g++    -c -o mbeenc.o mbeenc.cc
cc -g -O3 -Wall -std=c++0x -pthread   -c -o ambe.o ambe.c
cc1: warning: command line option ‘-std=c++11’ is valid for C++/ObjC++ but not for C
g++ -g -O3 -Wall -std=c++0x -pthread -c -o MBEVocoder.o MBEVocoder.cpp
MBEVocoder.cpp:21:10: fatal error: md380_vocoder.h: No such file or directory
   21 | #include <md380_vocoder.h>
      |          ^~~~~~~~~~~~~~~~~
compilation terminated.
make: *** [Makefile:19: MBEVocoder.o] Error 1

Many thanks -- Jeff


moderated Compile Error in M172DMR - md380_vocoder.h missing

Jeff - WA3PNY
 

I must be missing something obvious, I git cloned the Nostar branch of MMDVM_CM, and am attempting to compile M172DMR module, and it errors out not finding md380_vocoder.h  I'm compiling on a HP server, and a bunch of md380_vocoders seem to be nailed into ARM.  Here is what I am seeing:

bauerjv@penn-link4:~/Downloads/M17/MMDVM_CM/M172DMR$ sudo make
g++ -g -O3 -Wall -std=c++0x -pthread -c -o BPTC19696.o BPTC19696.cpp
g++ -g -O3 -Wall -std=c++0x -pthread -c -o Conf.o Conf.cpp
g++ -g -O3 -Wall -std=c++0x -pthread -c -o CRC.o CRC.cpp
g++ -g -O3 -Wall -std=c++0x -pthread -c -o DelayBuffer.o DelayBuffer.cpp
g++ -g -O3 -Wall -std=c++0x -pthread -c -o DMRData.o DMRData.cpp
g++ -g -O3 -Wall -std=c++0x -pthread -c -o DMREMB.o DMREMB.cpp
g++ -g -O3 -Wall -std=c++0x -pthread -c -o DMREmbeddedData.o DMREmbeddedData.cpp
g++ -g -O3 -Wall -std=c++0x -pthread -c -o DMRFullLC.o DMRFullLC.cpp
g++ -g -O3 -Wall -std=c++0x -pthread -c -o DMRLC.o DMRLC.cpp
g++ -g -O3 -Wall -std=c++0x -pthread -c -o DMRLookup.o DMRLookup.cpp
g++ -g -O3 -Wall -std=c++0x -pthread -c -o DMRNetwork.o DMRNetwork.cpp
g++ -g -O3 -Wall -std=c++0x -pthread -c -o DMRSlotType.o DMRSlotType.cpp
g++ -g -O3 -Wall -std=c++0x -pthread -c -o M17Network.o M17Network.cpp
g++ -g -O3 -Wall -std=c++0x -pthread -c -o Golay2087.o Golay2087.cpp
g++ -g -O3 -Wall -std=c++0x -pthread -c -o Golay24128.o Golay24128.cpp
g++ -g -O3 -Wall -std=c++0x -pthread -c -o Hamming.o Hamming.cpp
g++ -g -O3 -Wall -std=c++0x -pthread -c -o Log.o Log.cpp
g++    -c -o mbeenc.o mbeenc.cc
cc -g -O3 -Wall -std=c++0x -pthread   -c -o ambe.o ambe.c
cc1: warning: command line option ‘-std=c++11’ is valid for C++/ObjC++ but not for C
g++ -g -O3 -Wall -std=c++0x -pthread -c -o MBEVocoder.o MBEVocoder.cpp
MBEVocoder.cpp:21:10: fatal error: md380_vocoder.h: No such file or directory
   21 | #include <md380_vocoder.h>
      |          ^~~~~~~~~~~~~~~~~
compilation terminated.
make: *** [Makefile:19: MBEVocoder.o] Error 1

Many thanks -- Jeff


Re: Adding XLX Reflector

Steve N4IRS
 

On 4/10/21 4:05 PM, David - W9DWH via groups.io wrote:
Our local System Fusion repeater runs a Wires-X room.  Rather than set up a YSF or FCS reflector it was decided an XLX reflector would be used instead.  That way it's Wires-X room can also be accessed via DMR, D-Star, etc.

Setting up the XLX reflector on Pi-Star was a breeze.  However, since XLX is not native to DVS I'm trying to figure out how to add it.  I've done some research, here in the group, but a lot of info I've found so far is outdated now. I also keep seeing info that references Brandmeister and I don't need any connectivity directly from XLX to BM.  Therefore I'm a little lost at the moment. Is there an updated tutorial anywhere that will lead me through adding XLX connectivity only? 


Adding XLX Reflector

David - W9DWH
 

Our local System Fusion repeater runs a Wires-X room.  Rather than set up a YSF or FCS reflector it was decided an XLX reflector would be used instead.  That way it's Wires-X room can also be accessed via DMR, D-Star, etc.

Setting up the XLX reflector on Pi-Star was a breeze.  However, since XLX is not native to DVS I'm trying to figure out how to add it.  I've done some research, here in the group, but a lot of info I've found so far is outdated now. I also keep seeing info that references Brandmeister and I don't need any connectivity directly from XLX to BM.  Therefore I'm a little lost at the moment. Is there an updated tutorial anywhere that will lead me through adding XLX connectivity only? 


Re: DMR glitch on talk group 3142

Robert Rodriguez
 

It doesn’t look like the ClearNode lets me change servers, except for TGIF. I might be able to do it on the Linux config files directly. Oddly, I can receive your group 31679 ok on the 3103 server. Could be some bug with Brandmeister.

Bob Rodriguez
Kc3lyz


Re: Weird popup message

IK7VXC Mike
 

Thank you, Mike!


Re: DMR glitch on talk group 3142

Patrick Perdue
 

Have you tried another Brandmeister server? I have the same problem with another talkgroup, 31679, through server 3101, and it has nothing to do with DVSwitch, as I am using a hotspot and a DMR radio.

However, if I use 3021 instead, everything is fine. 3021 is in Canada, but it is the closest to me network-wise other than 3101, which is right in my back yard, so I often use that one rather than any of the U.S. servers.

Since I run the bridge for that talkgroup, I find this to be really strange, since my stuff is connected directly to 3101 through an interlink, but whatever.


On 4/9/2021 2:26 PM, Robert Rodriguez via groups.io wrote:
     I have a ClearNode AllStar node that uses a DVSwitch bridge to get to DMR via Brandmeister server 3103 in the US. For some reason, in the last 2 or 3 weeks, 
if I connect to talk group 3142 (Pennsylvania state-wide), I only hear the first transmission. If I re-key or reconnect, then I will hear one more each time, but it doesn't seem to stay on the group like you
would need for a net. We have our net on Tuesday nights at 8PM Eastern. The same talk group is ok via Openspot3 or one of the phone apps like DroidStar, and I haven't seen this problem on other talk
groups I use regularly via the ClearNode. I already checked with the ClearNode developer and he says everything looks ok on his end.

Any idea what's going wrong?

Bob Rodriguez
kc3lyz 


DMR glitch on talk group 3142

Robert Rodriguez
 

     I have a ClearNode AllStar node that uses a DVSwitch bridge to get to DMR via Brandmeister server 3103 in the US. For some reason, in the last 2 or 3 weeks, 
if I connect to talk group 3142 (Pennsylvania state-wide), I only hear the first transmission. If I re-key or reconnect, then I will hear one more each time, but it doesn't seem to stay on the group like you
would need for a net. We have our net on Tuesday nights at 8PM Eastern. The same talk group is ok via Openspot3 or one of the phone apps like DroidStar, and I haven't seen this problem on other talk
groups I use regularly via the ClearNode. I already checked with the ClearNode developer and he says everything looks ok on his end.

Any idea what's going wrong?

Bob Rodriguez
kc3lyz 


Re: Weird popup message

Mike Zingman - N4IRR
 

I will look into it.


Weird popup message

IK7VXC Mike
 
Edited

Hi. On one of my smartphones with the latest Dvswitch mobile version whenever I key up I get the folloing popup message (please see pic)
https://ibb.co/zVhxwNh 
Where is this log?
For the rest everything works just fine. So is it important?  How do I get rid of it?

Thanks
Mike IK7VXC


Re: Trying to get 2nd dashboard up

Komkit Listisard
 

Folks, I've got it working.  I missed one spot in config.php under "MMDVMINIPATH"

73, Kit


Trying to get 2nd dashboard up

Komkit Listisard
 
Edited

Folks, I have 2 mmdvm_bridge instances running.  Both are YSF2DMR bridges.  Bridges working fine no issue.  Dashboard YSF2DMR working fine, the 2nd dashboard showed up okay but there were in info.

indexes were in 2 separated directories. Most likely I am missing something in the index.php or other files, I just do not sure where to look.

Here is what my 2nd dashboard looks like.  There are logs for the 2nd dashboard but nothing is showing up.




Any suggestion would be greatly appreciated,

73, Kit


Re: DMR Master Not Showing?

Chuck
 

Yes, see it every day. DMR Master goes blank while my YSF Net shows the connection. When I reset it comes back but only for a day. 


Re: DMR Master Not Showing?

David J Taylor
 

On 08/04/2021 10:17, Daryl via groups.io wrote:
Good Morning.
During a recent update to my DVSwitch Server the AB version was updated to 1.6.2, since that time the default DMR Master does not show on the dashboard?
Previously it was showing just the BM IP address.
Checking  my BM Self Care Page my Switch is online and it continues to function.
If i change to another DMR Master ie DMR+ or TGIF and back it will then reconnect to BM and show the IP address again for BM?
Has anyone noticed this happening?
73
de
Daryl G0ANV
Daryl.

Mine shows just an IP address: 51.6.220.36 although the AB version is 1.6.2.

Not sure either how to update, or whether you can reverse the update if needed!

73,
David GM8ARV
--
SatSignal Software - Quality software for you
Web: https://www.satsignal.eu
Email: david-taylor@blueyonder.co.uk
Twitter: @gm8arv


DMR Master Not Showing?

Daryl
 

Good Morning.
During a recent update to my DVSwitch Server the AB version was updated to 1.6.2, since that time the default DMR Master does not show on the dashboard?
Previously it was showing just the BM IP address. 
Checking  my BM Self Care Page my Switch is online and it continues to function.
If i change to another DMR Master ie DMR+ or TGIF and back it will then reconnect to BM and show the IP address again for BM?
Has anyone noticed this happening?
73 
de
Daryl G0ANV


Searching the node list

Aerodan
 


My Allstar node list is pretty long, even culled down. A nice feature would be a search bar at the top of the node list drop down that allows for simple text and numeric search of the list. Thanks for considering! 


Re: MMDVM_Bridge Crashes as part of P25 <-> DMR link #mmdvm_bridge

Steve N4IRS
 

Sure

On 4/7/2021 9:01 AM, Andrew Lynch wrote:
Can do. Are you OK if I start an email thread off-list to coordinate with Sean N0PBA?

On Wed, Apr 7, 2021 at 8:00 AM Steve N4IRS <szingman@...> wrote:
I would like to setup a schedule to capture data rather then just filling a log with data hoping for a sample transmission. Can you get this scheduled?

Steve

On 4/7/2021 8:57 AM, Andrew Lynch wrote:
Steve - any luck with the watch on the P25 Reflector? I think Sunday morning when you reconnected we had a few crashes between me and K2KLN. Unfortunately all this P25 testing revealed another issue where my hotspot will "double" traffic on P25, which I nailed down Sunday morning as well. I have still yet to see it crash with hotspot traffic, only traffic from the N0PBA repeater link to the P25Reflector. 

I did update MMDVM_Bridge to 1.6.5 20210331 but doesn't seem to have had any effect.

Thanks!
-Andy, KDØIOE



--
Andrew Lynch (KDØIOE)
lurch89@... | https://kd0ioe.com/


Re: MMDVM_Bridge Crashes as part of P25 <-> DMR link #mmdvm_bridge

Andrew Lynch
 

Can do. Are you OK if I start an email thread off-list to coordinate with Sean N0PBA?


On Wed, Apr 7, 2021 at 8:00 AM Steve N4IRS <szingman@...> wrote:
I would like to setup a schedule to capture data rather then just filling a log with data hoping for a sample transmission. Can you get this scheduled?

Steve

On 4/7/2021 8:57 AM, Andrew Lynch wrote:
Steve - any luck with the watch on the P25 Reflector? I think Sunday morning when you reconnected we had a few crashes between me and K2KLN. Unfortunately all this P25 testing revealed another issue where my hotspot will "double" traffic on P25, which I nailed down Sunday morning as well. I have still yet to see it crash with hotspot traffic, only traffic from the N0PBA repeater link to the P25Reflector. 

I did update MMDVM_Bridge to 1.6.5 20210331 but doesn't seem to have had any effect.

Thanks!
-Andy, KDØIOE



--
Andrew Lynch (KDØIOE)
lurch89@... | https://kd0ioe.com/


Re: MMDVM_Bridge Crashes as part of P25 <-> DMR link #mmdvm_bridge

Steve N4IRS
 

I would like to setup a schedule to capture data rather then just filling a log with data hoping for a sample transmission. Can you get this scheduled?

Steve

On 4/7/2021 8:57 AM, Andrew Lynch wrote:
Steve - any luck with the watch on the P25 Reflector? I think Sunday morning when you reconnected we had a few crashes between me and K2KLN. Unfortunately all this P25 testing revealed another issue where my hotspot will "double" traffic on P25, which I nailed down Sunday morning as well. I have still yet to see it crash with hotspot traffic, only traffic from the N0PBA repeater link to the P25Reflector. 

I did update MMDVM_Bridge to 1.6.5 20210331 but doesn't seem to have had any effect.

Thanks!
-Andy, KDØIOE


Re: MMDVM_Bridge Crashes as part of P25 <-> DMR link #mmdvm_bridge

Andrew Lynch
 

Steve - any luck with the watch on the P25 Reflector? I think Sunday morning when you reconnected we had a few crashes between me and K2KLN. Unfortunately all this P25 testing revealed another issue where my hotspot will "double" traffic on P25, which I nailed down Sunday morning as well. I have still yet to see it crash with hotspot traffic, only traffic from the N0PBA repeater link to the P25Reflector. 

I did update MMDVM_Bridge to 1.6.5 20210331 but doesn't seem to have had any effect.

Thanks!
-Andy, KDØIOE

461 - 480 of 9532