Date   

Re: DVSwitch Status update

J P Watters <kc9kko@...>
 

Steve N4IRS,

Now you really have my attention. I have a pair of V.24 boards(P25NX version). Where do I find out how to configure things for the "MMDVM P25 Network". The P25NX network configuration seemed complicated to the point of questioning how reliable it would be. 

I will have to look at the version of the dual ethernet cisco router that I have on the scrap heap. It came out of a new fiber node a couple of years ago that was that was installed and decommissioned after a month. 

I have a APX portable that I have to keep handy for the public service side of life. P25 phase 2 rollout that was scheduled for last march, still in the going to roll out mode.  This would allow me to program a configuration for our UHF quantar repeater and link it to DMR talk groups.

WOW, one radio, for work and hobby.  And 0xFE receive for everybody!!!

..jpw
KC9KKO
Morris, IL





Re: DVSwitch Status update

Steve N4IRS
 

OK, that IS interesting. We are using the configuration that is the same as P25NX. A V.24 board and a Cisco router. Quantar_Bridge allow you to use a Quantar P25 native on the MMDVM P25 Network. No MMDVM board required.

Steve N4IRS

On 4/13/2018 11:10 AM, J P Watters wrote:
Steve N4IRS,

That is pretty cool news, since both myself and our local club are using Quantar's.

..jpw


Re: DVSwitch Status update

J P Watters <kc9kko@...>
 

Steve N4IRS,

That is pretty cool news, since both myself and our local club are using Quantar's.

..jpw


Re: HB_Bridge send stream back to master

Steve N4IRS
 

A couple of thoughts, my not be anything.
1: Is the node stanza in rpt.conf set duplex or simplex. Should be set to 0
2: Nope, just 1 thought.

On 4/13/2018 9:12 AM, Matthew 2E0SIP wrote:

Hi Guys,

I've noticed when I use HB_Bridge in conjunction with Analog_Bridge and Asterisk, when HB_Bridge receives a stream from the 'master' for decoding, it also sends the stream back to the master, resulting in these duplicate Last Heard entries.

Is this intentional, a bug, or have a I set something up wrong?



Thanks

Matthew
2E0SIP



HB_Bridge send stream back to master

Matthew 2E0SIP
 

Hi Guys,

I've noticed when I use HB_Bridge in conjunction with Analog_Bridge and Asterisk, when HB_Bridge receives a stream from the 'master' for decoding, it also sends the stream back to the master, resulting in these duplicate Last Heard entries.

Is this intentional, a bug, or have a I set something up wrong?



Thanks

Matthew
2E0SIP


Re: DVSwitch Status update

Steve N4IRS
 

James,
We are a few days away from the alpha release of the new programs MMDVM_Bridge and Quantar_Bridge. We will also release a alpha of Analog_Bridge that you will need to do P25 <---> DMR. We have been testing the P25 bridge on TG 31665 and do not expect any issues.

73, Steve N4IRS

On 4/12/2018 11:47 PM, James Riley kb9tzq wrote:
Just wondering how do I get the dvswitch toolkit I am interested in doing p25<>dmr and nxdn<>dmr


Re: DVSwitch Status update

James Riley kb9tzq
 

Just wondering how do I get the dvswitch toolkit I am interested in doing p25<>dmr and nxdn<>dmr


Re: AMBEtest4.py

Steve N4IRS
 

OK

On 4/12/2018 3:53 PM, Steve Siesel [K4KSA] wrote:

Nevermind…I found the correct command line syntax…..DV3000 is good.

 

Thanks,

Steve

 

 

From: main@DVSwitch.groups.io <main@DVSwitch.groups.io> On Behalf Of Steve Siesel [K4KSA]
Sent: Thursday, April 12, 2018 3:45 PM
To: DVSwitch@groups.io
Subject: [DVSwitch] AMBEtest4.py

 

My DMR<> ASL seems to be down….Upgraded to latest versions from Github, however I think there might be a problem with my AMBE USB vocoder….How long should the python script take to provide results? Its just hanging on “Testing Reset DV3000” ?

 

Steve

 



Re: AMBEtest4.py

Steve N4IRS
 

It should not hang, should report error and end.

On 4/12/2018 3:44 PM, Steve Siesel [K4KSA] wrote:

My DMR<> ASL seems to be down….Upgraded to latest versions from Github, however I think there might be a problem with my AMBE USB vocoder….How long should the python script take to provide results? Its just hanging on “Testing Reset DV3000” ?

 

Steve

 



Re: AMBEtest4.py

Steve Siesel [K4KSA]
 

Nevermind…I found the correct command line syntax…..DV3000 is good.

 

Thanks,

Steve

 

 

From: main@DVSwitch.groups.io <main@DVSwitch.groups.io> On Behalf Of Steve Siesel [K4KSA]
Sent: Thursday, April 12, 2018 3:45 PM
To: DVSwitch@groups.io
Subject: [DVSwitch] AMBEtest4.py

 

My DMR<> ASL seems to be down….Upgraded to latest versions from Github, however I think there might be a problem with my AMBE USB vocoder….How long should the python script take to provide results? Its just hanging on “Testing Reset DV3000” ?

 

Steve

 


AMBEtest4.py

Steve Siesel [K4KSA]
 

My DMR<> ASL seems to be down….Upgraded to latest versions from Github, however I think there might be a problem with my AMBE USB vocoder….How long should the python script take to provide results? Its just hanging on “Testing Reset DV3000” ?

 

Steve

 


Re: HBlink BM Issue Fixed

Corey Dean N3FE <n3fe@...>
 

I have not seen it and I am connected to 3102 as well as a client.  I have had my client running for well over a month.  When I do updates to 3102, like this morning, my hb-Bridge connects right back up.  I believe Cort may have fixed this a few months ago and the version I am running is from about a month and a half ago.

Corey n3fe


On Apr 11, 2018, at 8:26 PM, JJ Cummings <cummingsj@...> wrote:

I'm not sure if anyone is still experiencing this or not, but I am still seeing it.  Lots are not super interesting either:

DEBUG 2018-04-11 20:02:31,775 (BRANDMEISTER) Client maintenance loop started
DEBUG 2018-04-11 20:02:31,776 (BRANDMEISTER) RPTPING Sent to Master. Total Sent: 1187, Total Missed: 0, Currently Outstanding: 0
DEBUG 2018-04-11 20:02:36,771 (BRANDMEISTER) Client maintenance loop started
INFO 2018-04-11 20:02:36,772 (BRANDMEISTER) Sending login request to master 74.91.114.19:62031
INFO 2018-04-11 20:02:36,804 (BRANDMEISTER) Repeater Login ACK Received with 32bit ID: 1429456476
INFO 2018-04-11 20:02:36,837 (BRANDMEISTER) Repeater Authentication Accepted
INFO 2018-04-11 20:02:36,838 (BRANDMEISTER) Repeater Configuration Sent
INFO 2018-04-11 20:02:36,871 (BRANDMEISTER) Repeater Configuration Accepted
INFO 2018-04-11 20:02:36,872 (BRANDMEISTER) Connection to Master Completed
DEBUG 2018-04-11 20:02:41,772 (BRANDMEISTER) Client maintenance loop started
DEBUG 2018-04-11 20:02:41,773 (BRANDMEISTER) RPTPING Sent to Master. Total Sent: 0, Total Missed: 0, Currently Outstanding: 0
DEBUG 2018-04-11 20:02:41,811 (BRANDMEISTER) MSTPONG Received. Pongs Since Connected: 1

You can see where there is one MSTPONG missed and then it reconnects, but it doesn't always reconnect unless I restart the process.  I am running the updated changes and unfortunately this is as much debugging as I could do presently.

On Tue, Feb 6, 2018 at 7:10 AM, David <david@...> wrote:
Mine had stop twice on sun.    I am now try running everything from the hb_bridge portion.   Before I had pieced together the programs.

On Tue, Feb 6, 2018 at 7:51 AM, Cort N0MJS <n0mjs@...> wrote:
Guys,

Quick note – the changes to hblink.py seem to have fixed the Brandmeister disconnect problem. Been running for several days solid. Thanks again to Corey, N3FE. Without his help on the BM side this would have taken much longer to find!

0x49 DE N0MJS

Cort Buffington
785-865-7206







Re: HBlink BM Issue Fixed

JJ Cummings
 

I'm not sure if anyone is still experiencing this or not, but I am still seeing it.  Lots are not super interesting either:

DEBUG 2018-04-11 20:02:31,775 (BRANDMEISTER) Client maintenance loop started
DEBUG 2018-04-11 20:02:31,776 (BRANDMEISTER) RPTPING Sent to Master. Total Sent: 1187, Total Missed: 0, Currently Outstanding: 0
DEBUG 2018-04-11 20:02:36,771 (BRANDMEISTER) Client maintenance loop started
INFO 2018-04-11 20:02:36,772 (BRANDMEISTER) Sending login request to master 74.91.114.19:62031
INFO 2018-04-11 20:02:36,804 (BRANDMEISTER) Repeater Login ACK Received with 32bit ID: 1429456476
INFO 2018-04-11 20:02:36,837 (BRANDMEISTER) Repeater Authentication Accepted
INFO 2018-04-11 20:02:36,838 (BRANDMEISTER) Repeater Configuration Sent
INFO 2018-04-11 20:02:36,871 (BRANDMEISTER) Repeater Configuration Accepted
INFO 2018-04-11 20:02:36,872 (BRANDMEISTER) Connection to Master Completed
DEBUG 2018-04-11 20:02:41,772 (BRANDMEISTER) Client maintenance loop started
DEBUG 2018-04-11 20:02:41,773 (BRANDMEISTER) RPTPING Sent to Master. Total Sent: 0, Total Missed: 0, Currently Outstanding: 0
DEBUG 2018-04-11 20:02:41,811 (BRANDMEISTER) MSTPONG Received. Pongs Since Connected: 1

You can see where there is one MSTPONG missed and then it reconnects, but it doesn't always reconnect unless I restart the process.  I am running the updated changes and unfortunately this is as much debugging as I could do presently.

On Tue, Feb 6, 2018 at 7:10 AM, David <david@...> wrote:
Mine had stop twice on sun.    I am now try running everything from the hb_bridge portion.   Before I had pieced together the programs.

On Tue, Feb 6, 2018 at 7:51 AM, Cort N0MJS <n0mjs@...> wrote:
Guys,

Quick note – the changes to hblink.py seem to have fixed the Brandmeister disconnect problem. Been running for several days solid. Thanks again to Corey, N3FE. Without his help on the BM side this would have taken much longer to find!

0x49 DE N0MJS

Cort Buffington
785-865-7206







Re: HBLink <-> IPSC2 error message

Mike Norrbom
 

I have been able to link DMRlink to IPSC2 but I have not tried the HBlink yet.  I can try to connect up HBlink and see what happens.

 

Just out of curiosity, Why are you not connecting the repeaters directly to IPSC2?  What do you want HBlink to do for you?

 

Also, make sure you have the IPSC2 server setup to accept connections from a MMDVM connection for the HBlink software.

 

Thanks,

Mike

 

 

From: main@DVSwitch.groups.io [mailto:main@DVSwitch.groups.io] On Behalf Of f4ewi@...
Sent: Monday, April 9, 2018 2:57 PM
To: main@DVSwitch.groups.io
Subject: Re: [DVSwitch] HBLink <-> IPSC2 error message

 

Yes Mike we try to connect to a DMR+ IPSC2 server


Re: HBLink <-> IPSC2 error message

Thierry F4EWI
 

Yes Mike we try to connect to a DMR+ IPSC2 server


Re: HBLink <-> IPSC2 error message

Thierry F4EWI
 

No we just install HBLink (not HB_Bridge) like a client of IPSC2. IPSC2 see HBLink like a MMDVM.
we have not tested HB_Bridge yet! 


Re: HBLink <-> IPSC2 error message

Mike Norrbom
 

Are you trying to connect this to a DMR Plus IPSC2 Server?

 

Thanks,

Mike

 

 

From: main@DVSwitch.groups.io [mailto:main@DVSwitch.groups.io] On Behalf Of Steve N4IRS
Sent: Monday, April 9, 2018 2:21 PM
To: main@DVSwitch.groups.io
Subject: Re: [DVSwitch] HBLink <-> IPSC2 error message

 

From what branch did you install IPSC_Bridge and HB_Bridge?
Did you test HB_Bridge with a MMDVM login, without IPSC_Bridge running?

Steve N4IRS

On 4/9/2018 3:17 PM, f4ewi@... wrote:

Hello,
In first we install DMRLink for Motorola repeater and it's works perfectly
Now we try to install a link between HBLink and IPSC2 for MMDVM repeater. We have the following error message:


INFO 2018-04-09 21:14:18,912 (MASTER-1) Repeater Logging in with Radio ID: 208477, 92.184.97.127:51263 
INFO 2018-04-09 21:14:18,912 (MASTER-1) Sent Challenge Response to 208477 for login: 2089173234 
INFO 2018-04-09 21:14:18,995 (MASTER-1) Client 208477 has completed the login exchange successfully 
INFO 2018-04-09 21:14:19,760 (MASTER-1) Client F4EWI (208477) has sent repeater configuration 
ERROR 2018-04-09 21:14:19,846 (MASTER-1) Unrecognized command. Raw HBP PDU: 5250544f00032e5d20 
ERROR 2018-04-09 21:14:29,838 (MASTER-1) Unrecognized command. Raw HBP PDU: 5250544f00032e5d20 

can anyone help me?

 


Re: HBLink <-> IPSC2 error message

Steve N4IRS
 

From what branch did you install IPSC_Bridge and HB_Bridge?
Did you test HB_Bridge with a MMDVM login, without IPSC_Bridge running?

Steve N4IRS

On 4/9/2018 3:17 PM, f4ewi@... wrote:

Hello,
In first we install DMRLink for Motorola repeater and it's works perfectly
Now we try to install a link between HBLink and IPSC2 for MMDVM repeater. We have the following error message:

INFO 2018-04-09 21:14:18,912 (MASTER-1) Repeater Logging in with Radio ID: 208477, 92.184.97.127:51263 
INFO 2018-04-09 21:14:18,912 (MASTER-1) Sent Challenge Response to 208477 for login: 2089173234 
INFO 2018-04-09 21:14:18,995 (MASTER-1) Client 208477 has completed the login exchange successfully 
INFO 2018-04-09 21:14:19,760 (MASTER-1) Client F4EWI (208477) has sent repeater configuration 
ERROR 2018-04-09 21:14:19,846 (MASTER-1) Unrecognized command. Raw HBP PDU: 5250544f00032e5d20 
ERROR 2018-04-09 21:14:29,838 (MASTER-1) Unrecognized command. Raw HBP PDU: 5250544f00032e5d20 

can anyone help me?



HBLink <-> IPSC2 error message

Thierry F4EWI
 

Hello,
In first we install DMRLink for Motorola repeater and it's works perfectly
Now we try to install a link between HBLink and IPSC2 for MMDVM repeater. We have the following error message:

INFO 2018-04-09 21:14:18,912 (MASTER-1) Repeater Logging in with Radio ID: 208477, 92.184.97.127:51263 
INFO 2018-04-09 21:14:18,912 (MASTER-1) Sent Challenge Response to 208477 for login: 2089173234 
INFO 2018-04-09 21:14:18,995 (MASTER-1) Client 208477 has completed the login exchange successfully 
INFO 2018-04-09 21:14:19,760 (MASTER-1) Client F4EWI (208477) has sent repeater configuration 
ERROR 2018-04-09 21:14:19,846 (MASTER-1) Unrecognized command. Raw HBP PDU: 5250544f00032e5d20 
ERROR 2018-04-09 21:14:29,838 (MASTER-1) Unrecognized command. Raw HBP PDU: 5250544f00032e5d20 

can anyone help me?


Re: DMRlink issue

Themis Floros SV4QXF
 

Hi Cort , my configuration is basic for the moment , i try to find way to connect with IPSC2  , at first tests i try to use  DMRLink as MASTER <-> IPSC2 and take the upper msg error , now try as PEER <-> IPSC2 and show to working and stay connected. Next steps is to configure the bridge.

Maybe all config is wrong

[IPSC2_GR_PEER]
ENABLED: True
RADIO_ID: 202091
IP:
PORT: 50000
ALIVE_TIMER: 5
MAX_MISSED: 20
PEER_OPER: True
IPSC_MODE: DIGITAL
TS1_LINK: True
TS2_LINK: True
CSBK_CALL: False
RCM: False
CON_APP: False
XNL_CALL: False
XNL_MASTER: False
DATA_CALL: True
VOICE_CALL: True
MASTER_PEER: False
AUTH_ENABLED: True
AUTH_KEY: 7XX57XX5XX
MASTER_IP: 81.4.XXX.XXX
MASTER_PORT: 56002
GROUP_HANGTIME: 5