Re: hblink.py - CRITICAL UPDATE
It's a branch of HBLink, just like IPSC_Bridge is a branch of DMRLink.
JJC
It's a branch of HBLink, just like IPSC_Bridge is a branch of DMRLink.
JJC
|
By
JJ Cummings
·
#843
·
|
|
Re: hblink.py - CRITICAL UPDATE
I do not remember where I found HB_Bridge the first time but I can not find the updated version.
I do not remember where I found HB_Bridge the first time but I can not find the updated version.
|
By
David
·
#842
·
|
|
Re: Invalid command from BrandMeister
#brandmeister
I find that odd as well, since I know I’ve had multiple conversations about using HBlink with the Brandmeister Network and have setup multiple connections to it for various bridges. Mark, Corey,
I find that odd as well, since I know I’ve had multiple conversations about using HBlink with the Brandmeister Network and have setup multiple connections to it for various bridges. Mark, Corey,
|
By
Steven Blackford
·
#841
·
|
|
Re: Invalid command from BrandMeister
#brandmeister
I have never had them tell me to not use HB. I don't see a reason to ask again. Nor do I think we need to discourage people from using it.
I have never had them tell me to not use HB. I don't see a reason to ask again. Nor do I think we need to discourage people from using it.
|
By
Steve N4IRS
·
#840
·
|
|
Re: Invalid command from BrandMeister
#brandmeister
Steve, might you ask them about it, or should we just leave it alone? My stance has been to just sorta leave it alone and not *encourage* people doing it.
--
Cort Buffington
H: +1-785-813-1501
M:
Steve, might you ask them about it, or should we just leave it alone? My stance has been to just sorta leave it alone and not *encourage* people doing it.
--
Cort Buffington
H: +1-785-813-1501
M:
|
By
Cort N0MJS <n0mjs@...>
·
#839
·
|
|
Re: Invalid command from BrandMeister
#brandmeister
I have never been told by Artem or Rudy not to use HB to connect to BM. Thry sre well aware that quite a few people are using HB to connect an number of devices and protocols to BM.
I have never been told by Artem or Rudy not to use HB to connect to BM. Thry sre well aware that quite a few people are using HB to connect an number of devices and protocols to BM.
|
By
Steve N4IRS
·
#838
·
|
|
Re: Invalid command from BrandMeister
#brandmeister
I was thinking the same Cort, do the Zingmen know any different?
Sent from Outlook
From: main@DVSwitch.groups.io <main@DVSwitch.groups.io> on behalf of Cort N0MJS <n0mjs@...>
Sent: 04 February 2018
I was thinking the same Cort, do the Zingmen know any different?
Sent from Outlook
From: main@DVSwitch.groups.io <main@DVSwitch.groups.io> on behalf of Cort N0MJS <n0mjs@...>
Sent: 04 February 2018
|
By
Peter M0NWI
·
#837
·
|
|
Re: Invalid command from BrandMeister
#brandmeister
The reason you don’t see me getting too involved in connecting to Brandmeister is that, when I first released HBLink, Brandmeister had prohibited the use of HBlink to connect to their
The reason you don’t see me getting too involved in connecting to Brandmeister is that, when I first released HBLink, Brandmeister had prohibited the use of HBlink to connect to their
|
By
Cort N0MJS <n0mjs@...>
·
#836
·
|
|
Re: Invalid command from BrandMeister
#brandmeister
Thanks, if you can send your configuration here
Thanks, if you can send your configuration here
|
By
Andrii Misyurko
·
#835
·
|
|
Re: Invalid command from BrandMeister
#brandmeister
Hello,
Communication with BM servers works despite of the error I have reported on this issue. I was just testing HB Conference Bridge and I got it work. Time has passed but I may have the
Hello,
Communication with BM servers works despite of the error I have reported on this issue. I was just testing HB Conference Bridge and I got it work. Time has passed but I may have the
|
By
Veijo Arponen OH4VA
·
#834
·
|
|
Re: Invalid command from BrandMeister
#brandmeister
But I am not able to receive groups of Brandmeister and back. May be I have not correctly configured the client?
But I am not able to receive groups of Brandmeister and back. May be I have not correctly configured the client?
|
By
Andrii Misyurko
·
#833
·
|
|
Re: Invalid command from BrandMeister
#brandmeister
Just means it received something it doesn’t understand. Doesn’t necessarily indicate there will be a problem. If you’re not experiencing any particular failure associated with the occurrence of
Just means it received something it doesn’t understand. Doesn’t necessarily indicate there will be a problem. If you’re not experiencing any particular failure associated with the occurrence of
|
By
Cort N0MJS <n0mjs@...>
·
#832
·
|
|
Re: Invalid command from BrandMeister
#brandmeister
????
By
Andrii Misyurko
·
#831
·
|
|
Re: hblink.py - CRITICAL UPDATE
HB_Bridge has taken up Cort's changes as well as updated any other component that has changed to date.
HB_Bridge has taken up Cort's changes as well as updated any other component that has changed to date.
|
By
Mike Zingman - N4IRR
·
#830
·
|
|
Re: hblink.py - CRITICAL UPDATE
Remember the HB_Bridge branch has not been fix yet.
Steve
Remember the HB_Bridge branch has not been fix yet.
Steve
|
By
Steve N4IRS
·
#829
·
|
|
Re: hblink.py - CRITICAL UPDATE
I am loading it now on my stuff to see if it will fix the issue.
Thank you
I am loading it now on my stuff to see if it will fix the issue.
Thank you
|
By
David
·
#828
·
|
|
hblink.py - CRITICAL UPDATE
Folks,
Today I identified and corrected to critical problems with hblink.py in CLIENT mode, and have pushed to the master branch on GitHub. The HB_Bridge branch is also affected, but not updated by
Folks,
Today I identified and corrected to critical problems with hblink.py in CLIENT mode, and have pushed to the master branch on GitHub. The HB_Bridge branch is also affected, but not updated by
|
By
Cort N0MJS <n0mjs@...>
·
#827
·
|
|
Re: Analog Bridge and HBBridge
With a miss count of 1 it will not do a full restart on its own. I have to kill it manually and restart it.
With a miss count of 1 it will not do a full restart on its own. I have to kill it manually and restart it.
|
By
David
·
#826
·
|
|
Strange problem with HB_Bridge and Analog_Bridge
I have been testing the following setup and have been getting a strange error on the Brandmeister master server.
I have configured a private node on my existing Allstar server and now have
I have been testing the following setup and have been getting a strange error on the Brandmeister master server.
I have configured a private node on my existing Allstar server and now have
|
By
Ian Tulley
·
#825
·
|
|
Re: Analog Bridge and HBBridge
Probably set the missed counter to 1 also
Probably set the missed counter to 1 also
|
By
Cort N0MJS <n0mjs@...>
·
#824
·
|