DVSwitch not connecting to Brandmeister
Roger Davies
Hi All,
For some reason, my dvs server is not connecting to BM. It was working fine, but now it doesn't look like it's connecting to BM servers. I did update the dvs server to the latest version. I don't know if it's a problem on my side or BM's. When I check the BM server list to see if I'm connected, the BM list page says it can't be reached. Any ideas for me to start trouble shooting? TIA, Roger N6DVZ
|
|
"When I check the BM server list to see if I'm connected, the BM
list page says it can't be reached."
toggle quoted messageShow quoted text
Does this mean you can't go to selfcare with a browser? Steve N4IRS
On 6/10/2021 10:31 AM, Roger Davies
wrote:
Hi All,
|
|
Roger Davies
I can get into self care. My hotspot security is set up and matches the dvs BM password as well
|
|
check /var/log/mmdvm/MMDVM_Bridge- todays date.
toggle quoted messageShow quoted text
On 6/10/2021 12:17 PM, Roger Davies
wrote:
I can get into self care. My hotspot security is set up and matches the dvs BM password as well
|
|
Roger Davies
I know the dvs server is connected to the internet as I can SSH into it from outside my network.
|
|
Roger Davies
Thanks Steve.
Will do and let you know what I find.
|
|
Roger Davies
Hi Steve,
I see this in the log file: M: 2021-06-10 00:03:24.594 DMR, Opening DMR Network E: 2021-06-10 00:04:34.608 DMR, Connection to the master has timed out, retrying connection I: 2021-06-10 14:00:29.786 DMR Network Parameters I: 2021-06-10 14:00:29.786 Address: 3103.master.brandmeister.network I: 2021-06-10 14:00:29.786 Port: 62031 I: 2021-06-10 14:00:29.786 Local: 62032 I: 2021-06-10 14:00:29.786 Jitter: 360ms I: 2021-06-10 14:00:29.786 Slot 1: disabled I: 2021-06-10 14:00:29.786 Slot 2: enabled
I: 2021-06-10 14:00:29.786 Mode Hang: 3s
|
|
In MMDVM_Bridge.ini
toggle quoted messageShow quoted text
1: check your password in [DMR Network] 2: check Duplex=0 in [General] 3: Check RXFrequency and TX Frequency match in [Info] Steve N4IRS
On 6/10/2021 3:24 PM, Roger Davies
wrote:
Hi Steve,
|
|
Roger Davies
What is the path to MMDVM_Bridge.ini? I know enough to be dangerous.... lol Thanks
|
|
/opt/MMDVM_Bridge/MMDVM_Bridge.ini
toggle quoted messageShow quoted text
On 6/10/2021 3:43 PM, Roger Davies
wrote:
|
|
Roger Davies
These all look good:
1: check your password in [DMR Network] 2: check Duplex=0 in [General] 3: Check RXFrequency and TX Frequency match in [Info] [General] Callsign=N6DVZ Id=314900111 Timeout=180 Duplex=0
[Info] RXFrequency=222340000 TXFrequency=222340000
|
|
Roger Davies
Should I try to change the master address from Address=3103.master.brandmeister.network to Address= 74.91.118.251? Use the IP rather than URL?
|
|
Did you say you turned on hot spot security?
Sent via smoke signal (AT&T)
From: main@DVSwitch.groups.io <main@DVSwitch.groups.io> on behalf of Roger Davies <1n6dvz@...>
Sent: Thursday, June 10, 2021 3:58:07 PM To: main@DVSwitch.groups.io <main@DVSwitch.groups.io> Subject: Re: [DVSwitch] DVSwitch not connecting to Brandmeister Should I try to change the master address from Address=3103.master.brandmeister.network to Address= 74.91.118.251?
Use the IP rather than URL?
|
|
Roger Davies
Hotspot security is on with a password.
|
|
Make sure AirSecurity is off.
toggle quoted messageShow quoted text
If it's off, change your password in selfcare and match it in MMDVM_Bridge.ini Steve N4IRS
On 6/10/21 4:40 PM, Roger Davies wrote:
Hotspot security is on with a password.
|
|
Roger Davies
My air security is off off and Hotspot security is on.
I'll change the password and see what happens.
|
|
Changed password and no luck.
Would the SSL cert expiring cause me any problems? I cant hear anything on DVSMobile either. Thanks for you patience.
|
|
toggle quoted messageShow quoted text
On 6/10/21 6:00 PM, Roger Davies wrote:
Changed password and no luck.
|
|
Roger Davies
email sent.
|
|