Testing HBlink


 

Here are my observations:

 

Running  setup

 

        à34001                                à31003                                             62031

AST ß       à  Analog_Bridge ß        à HB_Bridge ß   àhblink>ß      à MMDVM

        ß32001                                ß31000

 

 

Allstar  node connected  to  IaxRpt console

 

All  IaxRpt consoles messages are OK .

 

PTT from  DMR radio shows  the following  on HB-Bridge console ( Seems OK)

 

                INFO 2017-06-21 13:53:27,368 Voice Transmission Start on TS 1 and TG BrandMeister (9) from VE2DJE

 

PTT from  DMR radio shows OK on Analog_Bridge console

 

                I: 2017-06-21 17:55:43.642 Begin TX: src=3022368 rpt=302236 dst=9 slot=1 cc=1

                Begin TX: src=3022368 rpt=302236 dst=9 slot=1 cc=1

 

Audio received on IAxrpt console is  white noise only….

 

TX from  IAXrpt Allstar console  shows OK on Analog_Bridge console

 

                M: 2017-06-21 17:58:53.474 PTT on

                M: 2017-06-21 17:58:56.542 PTT off (keyed for 3068 ms)

 

TX from  IAXrpt Allstar console  shows OK on  HB-Bridge console

 

                INFO 2017-06-21 13:59:49,675 (MASTER-1) Begin AMBE encode STREAM ID: 387864                                                                                                  7194 SUB: 3022387 (3022387) REPEATER: 302238 (302238) TGID BrandMeister (9)                                                                                                  , TS 1

                DEBUG 2017-06-21 13:59:49,801 (MASTER-1) import_datagramReceived

                /

                /

                /

                /

                DEBUG 2017-06-21 13:59:51,931 (MASTER-1) import_datagramReceived

                DEBUG 2017-06-21 13:59:51,936 (MASTER-1) End AMBE encode STREAM ID: 3878647                                                                                                  194 FRAMES: 31

 

Receiving  Callsign properly on DMR radio,  No audio…..

 

Tried to change  ambeSize  from 49 to 72 in Analog_Bridge.ini …..

Checked for TS1 TG9 ok in radio

Commented out  all [RULES] in HB_Bridge.conf

 

I suspect my Thumbdv , I have ordered  another one ……

 

Any clue on what I should check …..


Richard VE2DJE

 

.

 

 

 

 

 

Provenance : Courrier pour Windows 10

 


Steve N4IRS
 

Richard,
Please show us the output of Analog_Audio at startup.

Steve


Mike Zingman - N4IRR
 

What hardware/computer are you running the Analog_Bridge on?  Is the DV3000 connected locally or is it on an AMBE server?
We have seen that the DV3000 is very sensitive to power from the USB port and looking to see if yours is producing proper voltage levels.